Fotonic Plug-in Module

Fotonic Plug-in Module 2017-08-22T04:06:16+00:00

Fotonic Plug-in Module

Undoubtedly an essential measurement tool for process automation, quality control and tool automation control.

Sensitive Fiber Optic Measurement Sensors for nanomotion and vibration

Measure Dynamic Edge Position, Displacement, and Vibration at frequencies up to 500 kHz. The unique fiber optic probe design can accommodate a wide range of target reflectivity or shape, making it ideal for wide variety of applications such as ultrasonic horn vibration or Piezo electric materials studies.

Features

Random Fiber Distribution- As the probe-to-target distance increases, increasing amounts of light are proportionally captured by the receive fibers. The result is a very sensitive, linear output response (Range 1). A continued increase in probe gap will proportionally reduce the amount of light received, results in a sensitive, linear output response (Range 2) with a large measurement range and standoff distance.

Model Specifications

Product Info Technical Specifications
P/N Model Measurement Range Stand-Off Resolution Type Frequency Response Request Info
8500-1011 Plug-in Module: MTI-2020R 0.102mm (4mils) – 0.305mm (12mils) 0.127mm (5mils) – 0.508mm (20mils) 0.01µm (1µin) – 0.1µm (1µin) Fiber Optic Module 120kHz Request Infomation on Plug-in Module: MTI-2020R
8500-1012 Plug-in Module: MTI-2032R 0.127mm (5mils) – 1.016mm (40mils) 0.127mm (5mils) – 0.889mm (35mils) 0.01µm (1µin) – 0.1µm (1µin) Fiber Optic Module 120kHz Request Infomation on Plug-in Module: MTI-2032R
8500-1013 Plug-in Module: MTI-2047R 0.127mm (5mils) – 1.016mm (40mils) 0.127mm (5mils) – 1.118mm (44mils) 0.01µm (1µin) – 0.1µm (1µin) Fiber Optic Module 130kHz Request Infomation on Plug-in Module: MTI-2047R
8500-1014 Plug-in Module: MTI-2062R 0.152mm (6mils) – 1.524mm (60mils) 0.127mm (5mils) – 1.778mm (70mils) 0.01µm (1µin) – 0.1µm (1µin) Fiber Optic Module 150kHz Request Infomation on Plug-in Module: MTI-2062R
8500-1015 Plug-in Module: MTI-2062H 0.762mm (30mils) – 1.905mm (75mils) 0.762mm (30mils) – 3.81mm (150mils) 0.01µm (1µin) – 0.1µm (1µin) Fiber Optic Module 150kHz Request Infomation on Plug-in Module: MTI-2062H
8500-1016 Plug-in Module: MTI-2125R 0.152mm (6mils) – 3.556mm (140mils) 0.178mm (7mils) – 3.048mm (120mils) 0.01µm (1µin) – 0.1µm (1µin) Fiber Optic Module 190 kHz Request Infomation on Plug-in Module: MTI-2125R
8500-1017 Plug-in Module: MTI-2125H 1.778mm (70mils) – 4.445mm (175mils) 1.27mm (50mils) – 7.62mm (300mils) 0.01µm (1µin) – 0.1µm (1µin) Fiber Optic Module 150kHz Request Infomation on Plug-in Module: MTI-2125H
8500-1018 Plug-in Module: MTI-2125CTI 0.508mm (20mils) – 3.556mm (140mils) 0.762mm (30mils) – 5.588mm (220mils) 0.01µm (1µin) – 0.1µm (1µin) Fiber Optic Module 150kHz Request Infomation on Plug-in Module: MTI-2125CTI
8500-1019 Plug-in Module: MTI-2032RX High Resolution 0.036mm (1.4mils) – 4.445mm (175mils) 0.038mm (1.5mils) 0.01µm (1µin) – 0.1µm (1µin) Fiber Optic Module 100kHz Request Infomation on Plug-in Module: MTI-2032RX High Resolution
8000-4237 Plug-in Module: MTI-RC200 2.54mm (100mils) 2.54mm (100mils) 0.01µm (1µin) – 0.1µm (1µin) Fiber Optic Module 100kHz Request Infomation on Plug-in Module: MTI-RC200
8500-1020 Plug-in Module: MTI-2047E 0.127mm (5mils) – 0.051mm (2mils) Fiber Optic Module 100kHz Request Infomation on Plug-in Module: MTI-2047E
8500-1021 Plug-in Module: MTI-2062E 0.191mm (7.5mils) – 0.061mm (2.4mils) Fiber Optic Module 100kHz Request Infomation on Plug-in Module: MTI-2062E
Not finding what you’re looking for? MTI offers custom solutions More Info About MTI’s Custom Solutions

Industries & Applications For This Product

Industry Measurement Type Applications
Semiconductor Positioning Tape Cartridge Movement
Power Generation Amplitude Nuclear heat exchanger vibration
Research & Development Amplitude Piezoceramic, 1-3 PZT / polymer composite and PVDF film
Research & Development Displacement Piezoelectric stack motion
Request Info
Where to Buy
Click Here
If your application requires custom sensors
Click Here

Accessories

P/N Image Model Product Description
8000-4204 FS-3 (8000-4204) Image FS-3 Fotonic Probe Mount and Positioning Fixture – adjustable fixture to support and position probes over the target being measured. The system consists of a probe clamp, 2 positioning arms, magnetic base, c-clamp base and a micrometer with a 0.28″ (7mm) travel. The probe clamp holds probes up to 0.125 in. (3.2mm) in diameter with a reach of approximately 6″ (152mm).

Technology Principles

At MTI Instruments, we offer advanced sensing and physical measurement technology in products that range from basic sensors to complete, fully integrated measurement systems.

View Our Technology Principles
Request Info
Where to Buy
Click Here
If your application requires custom sensors
Click Here

Related Products

Looking for similar or complementary products? Browse the following products.

We make every effort, if feasible, to maintain, service and support  our legacy products.